Courtesy light in step mode (PP). The output COR is managed from the remote control.
The remote control turns the courtesy light on and off. The parameter
(1)
Selecting courtesy light mode
Disabled.
ACTIVE. The light remains lit for the entire duration of the manoeuvre.
From 3 to 90 s. The light remains lit for the time period set after the manoeuvre is completed.
From 2 to 9 minutes. The light remains lit for the time period set after the manoeuvre is completed.
Enable safeguarded gate closure/opening.
Enabling this parameter ensures that the gate is not left open due to an incorrect and/or accidental command.
This function is NOT
• the gate receives a STOP command;
the sensitive edge intervenes, detecting an obstacle in the same direction in which the function is enabled.
If instead the sensitive edge detects an obstacle during the movement opposite to the one guaranteed, the
function remains active.
• the number of closure attempts set by parameter
• the acquired position is lost (perform position recovery, see chapter 20).
Disabled. The parameter
Enabled.
After a period of time set with parameter
regardless of the parameter
Enabled.
If the gate is closed as a result of a step mode command, after a period of time set with parameter
If the gate is stopped by the obstacle detection system during a closure manoeuvre, the gate closes after a period
of time set with parameter
If the gate is stopped by the obstacle detection system during an opening manoeuvre, the gate closes after a period
of time set with parameter
Setting safeguarded closure/opening activation time
N.B.: this parameter is not visible if the value of parameter
Wait time settable from 2 to 90 s.
Wait time settable from 2 to 9 min.
Selection of the battery operation management
Setting a value different than
selected via parameter
The control unit always accepts commands until the battery is completely exhausted.
(1)
(1)
(1)
(1)
and
is not displayed.
, and then closes the gate.
.
.
and an error alert can be activated through the COR output via parameter
is ignored.
has been reached;
=
.
, the control
), and then the gate closes.
.