Idiomas disponibles

D-40
Parameter Reference
Parameter Name
No.
1533
Control Type
1743
This parameter will only become visible if Control Strategy is set to Vector Control and Control Type is set to Encoder Feedback, and
the drive is an AC30P/D
The parameter selects between encoder inputs :
MAIN SPD FEEDBACK : encoder option fitted or resolver option fitted. It corresponds to the option fitted in the I/O options. If selected,
the I/O option has to be set up in the corresponding option ( Resolver or Encoder )
SYSTEM BOARD SLOT 1 : encoder connected on SLOT1 if AC30D
SYSTEM BOARD SLOT 2 : encoder connected on SLOT 2 if AC30D
NONE : no encoder connected – corresponds to SENSORLESS control selected
If an encoder is available, encoder feedback control would normally be the preferred choice as it gives better speed control and higher
performance.

Functional Description

The motor selection is the first step in setting the control mode.
The selection of control strategy comes next, with the permitted settings as follows:
-
Induction motors can be run in either volts hertz mode or vector mode
-
Permanent magnet motors can only be run in vector control mode
If vector control is selected, and an encoder option or a resolver option is fitted, it is then necessary to choose whether to select vector control with
encoder feedback for improved performance.
Path
Setup::Motor Control::Control and Type
Parameters::Control Mode::Control
Mode
Default
Range
0
0:MAIN SPD FEEDBACK
1:SYSTEM BOARD SLOT 1
2:SYSTEM BOARD SLOT 2
3:NONE
Units
Writable
STOPPED