Parker AC30 Serie Manual Del Producto página 399

Ocultar thumbs Ver también para AC30 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Parameter Name
No.
Mot Inv Time Warning
0335
Only available for IM motor
Output information. Becomes TRUE when the overload is 5% of the maximum value before reducing the current
Mot Inv Time Active
0336
Only available for IM motor
Output information. Becomes TRUE when overload reaches 100% of the overload limit
Mot Inv Time Output %
0337
Only available for IM motor
Actual output limit of the inverse time motor protection.
This value is compared to the Stack Inv Time current limit output to provide the internal limit to the current limit module.
Mot I2T TC
0338
Only available for PMAC motor
Time constant of the motor, define in the PMAC Motor Data module
Mot I2T Active
0340
Only available for PMAC motor
Motor load has reached 105%
Mot I2T Warning
0341
Only available for PMAC motor
Motor load has reached 95%
AC30 series Variable Speed Drive
Path
Parameters::Motor Control::Motor Load
Parameters::Motor Control::Motor Load
Parameters::Motor Control::Motor Load
Parameters::Motor Control::Motor Load
Parameters::Motor Control::Motor Load
Parameters::Motor Control::Motor Load
Parameter Reference
Default
Range
x.x
0.0 to 600.0
0.000 to 1000000.000
D-107
Units
Writable
NEVER
NEVER
%
NEVER
s
NEVER
NEVER
NEVER