Parker AC30 Serie Manual Del Producto página 429

Ocultar thumbs Ver también para AC30 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Parameter Name
No.
Alignment Error
1807
Details of the last error recorded.
Reset to NO ERROR by running a new Alignment sequence.
NO ERROR : Everything ok. Alignment sequence is running
SHAFT LOCKED : the drive is locked in position.
AMPS : Not enough Amps to move the motor. Alignment Level too small
LOAD : Not enough Amps to move the motor. Is the motor free to rotate? Is there a load on the motor?
POLES : Bad motor poles number.
MOTOR UNCONNECTED : Motor phases disconnected. Verify the motor wiring
ENCODER : Something wrong detected on encoder speed and/or position.
INIT NEEDED : When Aligmnent On Power On = TRUE and a Start command has been detected. The drive should have tripped on
46 PMAC ALIGN ERROR
AC30 series Variable Speed Drive
Path
Parameters::Motor Control::Pos
Fbk Alignment
Parameter Reference
Default
Range
0:NO ERROR
1:SHAFT LOCKED
2:AMPS
3:LOAD
4:POLES
5:MOTOR UNCONNECTED
6:ENCODER
7:INIT NEEDED
D-137
Units
Writable
NEVER

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ac30pAc30d

Tabla de contenido