D-78
Parameter Reference
Parameter Name
No.
VHz User Freq
0423
Array of user defined frequency for V/f control
VHz User Volts
0435
Array of VHz User Volts for V/f control
Application User Boost
1633
User boost for V/Hz control from application
1549
Application Volts
Volts for V/Hz control, if fluxing law is done in the application
Energy Saving Lower Lim
1526
Energy Saving Lower Limit for application defined fluxing
Vsd Demand
0453
The amount of voltage applied in the direct or flux axis
Vsq Demand
0454
The amount of voltage applied in the quadrature or torque axis
Path
Parameters::Motor Control::Fluxing VHz
Parameters::Motor Control::Fluxing VHz
Parameters::Motor Control::Fluxing VHz
Parameters::Motor Control::Fluxing VHz
Parameters::Motor Control::Fluxing VHz
Parameters::Motor Control::Fluxing VHz
Parameters::Motor Control::Fluxing VHz
Default
Range
0.0 to 100.0
0.00
0.00 to 25.00
0.00
0.00 to 150.00
0.00
0.00 to 1.00
x.x
x.x
Units
Writable
STOPPED
%
%
STOPPED
%
ALWAYS
%
ALWAYS
ALWAYS
NEVER
%
%
NEVER
AC30 series Variable Speed Drive