D-136
Parameter Reference
Parameter Name
No.
Wiring direction of the motor phase :
-
STANDARD : U V W : position and phase U V W are rotating in the same direction
-
REVERSE : U W V : position and phase U V W are not rotating in the same direction. V and W have been inverted
internally to the drive.
If the Alignment is completed, then this parameter is written back to 1809 PMAC Wiring
Alignment State
1805
State of Alignment sequence :
OFF : No Alignment sequence
ON MANUAL : Alignment Method = MANUAL or DIRECTION TEST + Alignment Enable = TRUE.
ON AUTO : Alignment Method = AUTOMATIC + Alignment Enable = TRUE.
ERROR : An error occurred during the Alignment. See Alignment error for possible diagnostics
ENDED : When Alignment sequence is run and successfully completed
Alignment Ended
1806
TRUE : Alignment sequence ended successfully.
FALSE : No Alignment sequence or Alignment sequence in progress
Path
Parameters::Motor Control::Pos
Fbk Alignment
Parameters::Motor Control::Pos
Fbk Alignment
Default
Range
0:OFF
1:ON MANUAL
2:ON AUTO
3:ERROR
4:ENDED
Units
Writable
NEVER
NEVER