Parker AC30 Serie Manual Del Producto página 482

Ocultar thumbs Ver también para AC30 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

D-190
Parameter Reference
Parameter Name
No.
Inv Time Active
0353
The drive protection is limiting the output current
(*) : Depending on the frame size, overload capabilities are reduced when the electrical speed is below 3Hz and with the heatsink temperature. Refer
to Parker Hannifin Manufacturing for detailed values.
Above 3Hz electrical speed, overload capabilities are those defined by the 0390 Duty Selection.
Functional Description
Feedback Amps
Move to Stack %
Convert to Motor %
Short Overload : is using 180% of the Heavy Duty rating, for 3s.
Long Overload : is using the overload mode selected in 0390 Duty Selection.
Inv Time in Motor % is used to limit the current. It is one of the inputs of the Current Limit Function features
Path
Parameters::Motor Control::Stack Inv
Time
Stack Short overload
arbitration
Stack Long overload
Motor Load (Only for IM Motor)
Motor overload (
150%, 60s)
Default
Range
Inv Time Output
Convert to Motor %
Min
Inv Time in Motor %
Units
Writable
NEVER
AC30 series Variable Speed Drive

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ac30pAc30d

Tabla de contenido