D-46
Parameter Reference
Parameter Name
Log Parameters[0]
to
Log Parameters[7]
Defines up to 8 parameters to log.
Log File Size
The size of the currently active log file. This may be used in the application together with "1836 Log to new File" to force the Data
Logger to create a new log file when the current file reaches an arbitrary size. This value is zero when 1835 Log Enable is FALSE.
Functional Description
The Log file is designed to be easy to read in either a text editor or a spreadsheet application, such as Microsoft Excel. The file format has the
extension "csv" which stands for Comma Separated Variables.
Once each period, the drive records the nominated parameter values and writes these to a line in the log file. The data values are separated by
columns, and the line is terminated with a carriage return line feed.
Below is an example configuration for the Data Logger.
No.
Path
1843
to
Parameters::Device Manager::Data Logger
1850
Parameters::Device Manager::Data Logger
1841
Default
Range
0000
0000 to 3131
Units
Writable
ALWAYS
NEVER
AC30 series Variable Speed Drive