Descargar Imprimir esta página

Sammic AT-3 Manual De Instrucciones página 63

Ocultar thumbs Ver también para AT-3:

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
On completion of the blast chilling/blast freezing cycle, when the needle probe has reached the right temperature or
the time period is finished, the buzzer sounds and the conservation phase begins. If the temperature controlled cycle
is not completed in the allotted time, the problem will be notified by displaying an alarm message.
The conservation phase is not timed and is only terminated when the
key is pressed for 2 seconds.
Defrosting is always enabled during a conservation phase.
While a cycle is being carried out, by pressing the
key it is possible to access an advanced page where the
working setpoints for the cycle in progress can be modified and all of the machine's internal status data displayed.
Pre-cooling
4.4
This is a refrigeration cycle of infinite duration that can precede all the operating cycles.
It can also be used as a refrigeration cycle of infinite duration.
10

Publicidad

loading

Este manual también es adecuado para:

At-5At-8At-10At-12At-14At-20