Once the desired cycle has been selected, by pressing the
key it is possible to add a phase (hard for blast
chilling, soft for blast freezing) that will be carried out preliminary to the standard phase, thus changing from a single
phase to a two phase cycle.
Example of a temperature controlled blast chilling cycle (needle), addition of a hard phase, quick change of the cabinet
setpoint for the soft phase and start cycle.
The selected cycle will offer either the pre-loaded settings for that cycle, or the settings of the last cycle carried out
(depending on the r36 parameter). By pressing
,it will be possible to quickly change the value of an
individual data item (set by parameter r35) within the permitted ranges.
Once the change has been made, press
to carry out the cycle.
Example of a temperature controlled blast freezing cycle (needle), conversion to time controlled cycle, quick change of
the blast freezing cycle duration and start cycle.
If it is a temperature controlled cycle, a test will be performed to check that the needle probe has been correctly
inserted in the food item to be blast chilled. If the test is not successful, the cycle automatically switches to time
controlled mode: the buzzer sounds and the type of cycle control is converted from temperature to time on the display.