A8
15
0
A10
5
0
A11
2
1
A12
5
0
A13
60
0
PAR.
DEFAULT
MIN.
F1
-1
-50
F3
2
0
F8
2
1
F15
15
0
F17
90
-50
F29
0
0
F30
0
0
F31
0
0
F32
0
0
F33
0
0
F46
15
0
Maximum temperature alarm delay ("HIGH TEMPERATURE"
240
min
code) from the start of conservation
Power failure duration sufficient for the power failure alarm to
be saved ("POWER FAILURE" code) when this is restored
240
min
0 = alarm not signalled
15
ºC
Parameter A1 and A4 differential
Duration of buzzer activation on completion of blast chilling and
240
s
blast freezing
240
s
Duration of alarm buzzer activation
MAX.
U.M.
EVAPORATOR AND CONDENSER FANS
Evaporator
switches
99
ºC
freezing/sanitation/ice cream hardening
see also parameter F8
Duration of evaporator fan-off time (while the evaporator fan is
15
min
off the compressor may be switched on, the defrost output is
de-activated and the evaporator fan stays off)
15
ºC
Parameter F1 and F17 differential
Evaporator fan delay from when the door is closed, or the door
240
s
switch input is deactivated
Cabinet temperature above which the evaporator fan switches
off during pre-cooling/blast chilling/blast freezing/sanitation/ice
199
ºC
cream hardening;
see also parameter F8
Fan operating mode during first phase of thawing:
1
- - - -
0 = in parallel with the compressor and thawing heater
1 = always on
Fan operating mode during second phase of thawing:
1
- - - -
0 = in parallel with the compressor and thawing heater
1 = always on
Fan operating mode during third phase of thawing:
1
- - - -
0 = in parallel with the compressor and thawing heater
1 = always on
Fan operating mode during fourth phase of thawing:
1
- - - -
0 = in parallel with the compressor and thawing heater
1 = always on
Fan operating mode during fifth phase of thawing:
1
- - - -
0 = in parallel with the compressor and thawing heater
1 = always on
Condenser temperature above which the condenser fan is
99
ºC
switched on
26
temperature
above
which
off
during
pre-cooling/blast
the
evaporator
fan
chilling/blast
EN