Access the SPECIAL CYCLES menu using the
key and select PRE-COOLING: at this point the working
SETPOINT setting screen is displayed, the value of which is given by parameter r12 but which can be modified using
the
keys. The next time that the
key is pressed the cycle starts.
Once the required cabinet setpoint has been reached, the buzzer sounds and the cycle continues and maintains the
cabinet temperature achieved until the
key is pressed for 2 seconds or until a blast chilling/blast freezing cycle
starts up.
If, on the other hand, blast chilling and blast freezing cycles are selected while a pre-cooling program is in progress,
the device will display the cycle settings.
During a pre-cooling cycle, defrosting is enabled.
In the event of a power failure, the cycle will be resumed.
Manual defrosting
4.5
A defrosting cycle can be started manually only if certain temperature conditions are met (see parameters d2 and d3).
Access the SPECIAL CYCLES menu using the
key and select DEFROSTING: at this point the word DEFROSTING
will appear and the next time
is pressed the cycle will start.
If the evaporator probe is present and the conditions for defrosting are not satisfied, when the START key is pressed,
the device returns to the SPECIAL CYCLES menu and defrosting is not carried out.
If a defrosting is set to be carried out with the door open (d1=3), the message "OPEN DOOR" will be displayed if it is
closed.