Descargar Imprimir esta página

Wilo T72 Instrucciones De Instalación Y Funcionamiento página 225

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1391
9.5.1
Maintenance intervals for normal
conditions
T 12
T 13
T 17
T 17.2
T 20
T 20.1
T 24
T 30
T 34
T 42
T 49
T 50.1
T 56
T 57
T 63.1
T 63.2
T 72
9.5.2
Maintenance intervals for harsh
conditions
9.6
Maintenance measures
Installation and operating instructions Wilo Motor T 12 ... 72 + EMU FA, Rexa SUPRA, Rexa SOLID
Maintenance and repair
pump and the installation must be checked regardless of the defined maintenance in-
tervals.
8000 operating hours or after 2 years at the latest
• = Carry out maintenance measures, − = do not carry out maintenance measures
*NOTICE! If a sealing chamber control is installed, the oil is changed according to the
indicator!
15000 operating hours or after 10 years at the latest
▪ General overhaul
Under harsh operating conditions, specified maintenance intervals must be shortened if
required. Harsh operating conditions include:
▪ Fluids with long-fibre components
▪ Turbulent inlet (e.g. due to air intake, cavitation)
▪ Strongly corroding or abrasive fluids
▪ Heavily gas generating fluids
▪ Operation at an unfavourable duty point
▪ Pressure surges
When using pumps under hard conditions, it is recommended to sign a maintenance
contract. Contact customer service.
WARNING
Sharp edges on the impeller and suction port!
Sharp edges can form on the impeller and suction port. There is danger of limbs be-
ing severed! Protective gloves must be worn to protect from cuts.
en