9.7
Replacing side brushes
9.8
Cleaning
9.8.1
Cleaning/replacing dust filter cartridges
68
1 Side brushes
2 Screws
Loosen 4 screws and remove the side brushes.
Insert new side brushes and fasten with four screws.
9.7.1
Converting the side deck
The conversion to the side scrubbing deck or side
brushes deck must be accomplished by Customer Ser-
vice; the sweeping level and the cleaning parameters
must be reset after the conversion.
DANGER
Risk of injury!
Remove the key before cleaning and maintenance
work!
Park the vehicle on a level surface.
Turn the ignition key to position "0" and remove it.
Activate parking brake.
CAUTION
Health hazard!
Wear a dust mask when working around the dust filter.
Observe safety regulations on the handling of fine par-
ticles.
Wear an eye shield!
ATTENTION
Do not use any hard objects for cleaning!
The dust filter cartridges are responsible for filtering and
retaining the dust suctioned up by the suction turbine dur-
ing sweeping.
Dedust the dust filter with the filter dedusting switch
each day during and after cleaning (see Chapter
"Cleaning | Dedusting the dust filter".
Remove and clean the dust filer from time to time.
Complete replacement every 1500 operating hours!
1 Suction blower cover
2 Handle
3 Screw
Open the screw and tilt the suction blower cover to-
wards the rear.