ENGLISH
4) Press the set button to show the current number on the display. Use the foam button or liquid button to choose the desired
number (see table below). Press the set button to set the flashing number.
No.
Setting
0
Setting A (mainly beer)
1
Setting B (mainly cocktail)
2
Setting C (mainly cocktail)
3
Setting D (optional)
Note: The sold out sensor is factory set to "0: Setting A (mainly beer)". The setting depends on the brand of beverage to
dispense. Check with your dealer/supplier.
5) Press the set button again to show "U07" on the display. Press and hold the set button for more than 3 seconds to complete
the setting.
Note: If no operation is performed for more than 1 minute, the dispensing mode is resumed. In that case, go back to step 2)
above.
10. USER SETTINGS
To make or change settings:
Press and hold the set button for 3 seconds to enter the setting mode (see "9. SOLD OUT SENSOR SETTING ("U07")").
To complete settings:
With "U_ _" on the display, press and hold the set button for 3 seconds to enter the dispensing mode.
The dispensing mode is also resumed if no operation is performed for more than 1 minute.
Item
Digital display
U01
(in dispensing mode)
U02 Log of number of mugs
U03 Number of flush cycles
Number of keg
U04
replacements
(reset frequency)
Dispense lamp
U05
brightness
Dispense lamp flashing
U06
duration
U07 Sold out sensor setting
0: No indication
1: Number of mugs (*)
* Number switches between the larger and smaller mugs when the mug
setting is changed.
* To reset, press and hold the stop button for 3 seconds.
Log of number of mugs for each reset in descending order
* Log is indicated in turn for each keg replacement by "U04".
* Log is indicated for both larger and smaller mugs when the mug setting is
changed.
* To reset all the current and past logs, press and hold the stop button for 3
seconds. This reset is not counted for "U04".
Number of flush cycles performed
* A flush cycle consists of liquid button operation (total 10 seconds) + foam
button operation (total 3 seconds) in the flush mode except when no
automatic dispensing action is made during the cycle.
* To reset, press and hold the stop button for 3 seconds.
Reset frequency for number of mugs
* Keg replacement is counted every time the number of kegs is reset by the
stop button operation.
* To reset, press and hold the stop button for 3 seconds.
Adjustment of dispense lamp brightness
Adjustment of dispense lamp flashing duration after completion of
dispensing
* The dispense lamp flashes to prevent another mug is placed while foam is
still dripping.
* Automatic dispensing action is not available while the lamp is flashing.
0: Setting A (mainly beer) / threshold: 2.2V
1: Setting B (mainly cocktail) / threshold: 2.5V
2: Setting C (mainly cocktail) / threshold: 2.8V
3: Setting D (optional) / threshold: optional
* The setting depends on the brand of beverage to dispense. Check with your
dealer/supplier.
Description
12
Default Setting Range
0
0 - 1
0
Up to 5 logs
0
0 - 9999
0
0 - 9999
6
1 - 8
1
0 - 10
0
0 - 3