ENGLISH
3) When restarting the unit, follow the procedures below:
II. 1. CLEANING BEER CIRCUIT
2. FILLING WATER TANK
3. CHECKS BEFORE OPERATION (DAILY)
4. START UP
5. SETTING LIQUID AND FOAM AMOUNTS
6. DISPENSING
7. SOLD OUT SENSOR
8. END OF DISPENSING OPERATION

2. BEFORE CALLING FOR SERVICE

If the dispenser does not work properly, check the following table before calling for service. If the problem still exists, turn off the
power switch (earth leakage breaker) and contact your dealer/supplier.
Do not attempt to repair the unit by yourself. Only qualified personnel may repair the unit.
Problem
Unit will not
The unit is unplugged.
start.
The fuse is blown out.
Power failure.
Beer is not
No ice in the water tank.
cold.
Less than 8 to 13 hours after the power
switch (earth leakage breaker) is turned on.
Ambient temperature is above 30°C.
No cooling water in the water tank.
The air inlet or outlet is blocked or not clean.
No beer is
The beer keg is empty.
dispensed.
The CO2 gas cylinder is empty.
The main valve of CO2 gas cylinder is closed. Open.
The regulator is set to "0".
The keg coupler is not attached to the beer
keg correctly.
The keg coupler handle is closed.
Beer cloggs the beer tap and the lever cannot
move smoothly.
Abnormal
Operation sound of the refrigeration unit or
noise.
condenser fan motor.
The foundation is not firm.
The foundation is not level.
Something is touching the unit.
Possible Cause
Plug in.
Contact your dealer/supplier.
Wait until power is resumed.
Wait until ice is produced.
Ice production takes 8 to 13 hours depending on ambient and
water temperatures. Wait for 8 to 13 hours before dispensing
beer.
Ventilate with a fan to lower ambient temperature.
Fill the water tank. See "II. 2. FILLING WATER TANK".
Clean or unblock. See "III. 9. AIR FILTER (BIWEEKLY)".
Replace with a new keg. See "II. 3. [d] REPLACING BEER
KEG".
Replace with a new cylinder. See "II. 3. [b] REPLACING CO2
GAS CYLINDER".
Adjust the regulator to a proper pressure. See "II. 3. [b]
REPLACING CO2 GAS CYLINDER".
Check and correct. See "II. 3. [d] REPLACING BEER KEG".
Open the beer circuit. See "II. 3. [d] REPLACING BEER KEG".
Disassemble and clean the beer tap. See "III. 6.
DISASSEMBLY AND CLEANING OF BEER TAP (WEEKLY)".
No problem.
Contact your dealer/supplier.
Contact your dealer/supplier.
Keep it away from the unit.