Descargar Imprimir esta página

Start Up; [A] Switching Mode; [B] Leading Beer To Tap; Setting Liquid And Foam Amounts - Hoshizaki DBF-AS65WE-EU Manual De Instrucciones

Dispensador automático de cerveza de barril

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 132
ENGLISH
6) Open the beer circuit.
Rotary type: Turn the keg coupler handle clockwise until it stops.
Vertical type: Push down the keg coupler handle until it locks in place.
7) Before dispensing beer, lead beer to the beer tap according to "4. [b] LEADING BEER
TO TAP".

4. START UP

In case of a gas leak, turn off the main gas supply and ventilate the room. To prevent sparks and resulting fire and explosion,
do not unplug the unit.
Do not use combustible spray or place volatile and flammable substances near the unit. They could catch fire from sparks.
If the power goes off, contact your dealer/supplier. To prevent electric shock or fire, do not turn it back on.
In case of trouble, unplug the unit or disconnect the main power supply, and immediately contact your dealer/supplier. To
prevent possible electric shock or fire, do not keep the unit in operation.
1) Plug in the unit.
2) The refrigeration unit and agitator motor start.
It takes about 8 to 13 hours from startup to completion of ice storage in the water tank. Dispensed beer may not be cold
enough until ice production completes.

[a] SWITCHING MODE

Each push of the flush button on the operation panel will switch between the ready mode and flush mode. In the ready mode,
the dispense lamp lights up. In the flush mode, the flush lamp lights up.

[b] LEADING BEER TO TAP

1) Check that the regulator adjust dial is set to the appropriate pressure specified by the
beer company.
2) Open the beer circuit.
Rotary type: Turn the keg coupler handle clockwise until it stops.
Vertical type: Push down the keg coupler handle until it locks in place.
3) Place a mug on the platform.
4) Press and hold the foam button to purge air out of the beer circuit through the foam nozzle. Release the foam button when no
more air is purged and a steady flow of foam is obtained. When beer reaches the sold out sensor, the sold out lamp goes off
and the ready lamp comes on.
5) Press the liquid button to check that clear beer is dispensed. Release the liquid button to stop beer.
If the liquid nozzle is used to purge air out of the beer circuit, liquid will splash out together with gas. When connecting or
replacing a beer keg, always use the foam nozzle to purge air.

5. SETTING LIQUID AND FOAM AMOUNTS

To reduce the risk of injury, do not put your fingers behind the platform while it is moving.
WARNING
IMPORTANT
IMPORTANT
CAUTION
16
Keg Coupler Handle
Rotary Type
Vertical Type
Keg Coupler Handle
Rotary Type
Vertical Type

Publicidad

loading