12) Turn the keg coupler clockwise to attach it to the cleaning tank.
Note: Wash the joint between the keg coupler and cleaning tank if it is not clean.
13) Open the main valve of the CO2 gas cylinder by turning it counterclockwise a few
times.
14) Turn the regulator adjust dial to set the pressure to "0.15" (MPa).
15) Open the beer circuit.
Rotary type: Turn the keg coupler handle clockwise until it stops.
Vertical type: Push down the keg coupler handle until it locks in place.
Note: If the cleaning tank is provided with a siphon tube, lay the cleaning tank with the ferrule at the top. If not, lay the
cleaning tank with the ferrule at the bottom.
Keg Coupler Handle
Rotary Type
16) Wait until the cleaning sponge and water come out of the liquid nozzle.
17) Turn the regulator adjust dial to set the pressure to "0" (MPa).
18) Close the main valve of the CO2 gas cylinder by turning it clockwise.
19) Check that CO2 gas stops coming out of the nozzle.
20) Close the beer circuit.
Rotary type: Turn the keg coupler handle counterclockwise until it stops.
Vertical type: Unlock and lift the keg coupler handle all the way up.
21) Turn the keg coupler counterclockwise to remove it from the cleaning tank.
22) Thoroughly wash and dry the cleaning sponge and store it for later use.
23) Repeat the above steps 9) to 22) until clear water comes out of the beer tap.
Note: Receive the water in a mug or glass to check its clearness. Repeat a few
times until water becomes clear.
24) Turn the union nut clockwise to remove the beer tap.
25) Loosen the cap nut to disassemble the beer tap. Fit the valve shaft in the
original (normal) direction while aligning the holes in the beer tap and valve
shaft (larger hole facing up), and tighten the cap nut.
Note: Assemble the beer tap correctly, or beer cannot be dispensed
properly.
26) Attach the beer tap on the unit by turning the union nut counterclockwise.
27) Wash the cleaning tank interior thoroughly, turn the tank upside down to dry, and cap it tightly for storage.
28) Hold the bottom of the operation panel unit and pull the front handle toward you to unlock. Pull down the operation panel unit
until it stops to cover up the beer tap lever.
Note: To prevent malfunction, do not pull down the operation panel unit with the beer tap removed.