STEP-BY-STEP MODE (PP)
00
OPENS - STOPS - CLOSES - STOPS - OPENS
01
PP CONDOMINIUM, command PP refreshes the rest time from fully opened
02
PP CONDOMINIALE, command PP closes from fully opened
03
OPENS – CLOSES – OPENS - CLOSES
04
OPENS – CLOSES – STOPS – OPENS
NOTE: parameter
Condominium means that the command PP is ignored when opening.
In installations where multiple users may arrive at the same time, and therefore trigger the radio
control while the gate is operating, is useful to ensure the completion of the opening: it is possible to
prevent two activations by different users from reversing the motion by closing the gate.
By setting the parameter to the value
command does not perform a closure but restarts the count of the rest time.
A5 00

Pre-flashing

00
OFF (the flashing light is only on when there is movement)
01
10
DURATION IN SECONDS of the early activation of the flashing
-
99
not performed when opening; 5 seconds of pre-flashing when closing
NOTE: parameter 5- in simplified mode
A6 00

Condominium function with PEDESTRIAN (PED)

00
OFF (pedestrian control performs AP-ST-CH-ST-AP- ...)
01
ON (pedestrian control operated when opening is ignored)
A7 00

Man present

00
OFF (the controls work normally)
01
ON (the gate only moves by holding down AP or CH)
The motors will only remain active in the presence of a continued command; only the commands AP
and CH are enabled; the motors will stop upon release of the command.
The commands must be positioned so as to be able to check the movement of the gate.
A8 00

Gate open light

00
when the gate is closed the light is off, otherwise it is on
slow flashing when opening, quick when closing, fixed from fully open, turns off twice in
01
succession every 15 seconds if the gate has stopped in the intermediate position
02
the SC output is used to supply power to the photocells and perform the test on them
The output SC in battery mode does not power the external loads when the doors are fully
03
open or fully closed; in the presence of network voltage the output SC always supplies power
04
as for value 03, and in addition even the phototest function is run
6-
in simplified mode
01
, if the gate is open, the activation of the step-by-step
35