ELECTRICS
Trouble
Spark plug becomes dirty
too frequently
Generator charging too low
or not at all
N° 8000A3632 (06-04)
16:15
Pagina C.9
All manuals and user guides at all-guides.com
TROUBLES AND REMEDIES
Cause
1. Mixture too rich
2. Air filter dirty
3. Piston rings worn
4. Piston or cylinder cane worn
1. Generator coil faulty
Remedy
Adjust carburettor
Clean
Replace
Replace
Replace
C.9