Set PROFIBUS address
Current
PB address
PROFIBUS
1...126
address
p0918 (126)
Memory
POWER ON
SET
p0918
Process data
CBE20 FW sel
transmission
p8835 (1)
CBE20
PROFINET
Ethernet
SINAMICS LINK
interface
EtherNet/IP
Modbus TCP
PROFIBUS
connection
<5>
<6>
RS485
AOP30/USS
<5>
interface
RS232
<1> p2040: for USS
p2047: for PROFIBUS
p8840: for Modbus TCP
<2> For p8839[0] = 99 is valid:
CBE20 inserted: corresponds to switch position 2.
CBE20 not inserted: corresponds to switch position 1.
<3> For p8839[1] = 99 is valid:
CBE20 inserted: corresponds to switch position 1.
CBE20 not inserted: corresponds to switch position 0.
<4> Not with stop of master CPU.
<5> Only one of the two interfaces – RS 485 (X178-3, 4) or RS 232 (X179-3, 4) –
may be used.
<6> Bus termination can be switched on/off with p50820.
<7> Monitoring is only performed if at least one "valid" cyclic telegram has been
received for the first time.
"Valid" means: Master is in operation and user data are transferred.
1
2
DO: CU_DC, DC_CTRL
PROFIdrive - PROFIBUS (PB) / PROFINET (PN) / USS, addresses and diagnostics
Field bus baud
4...13
p2020 (8)
PROFIBUS
1
3
4
5
Field bus protocol
p2030 (3)
PROFIBUS
3
protocol
1
0
USS
3
protocol
1
PPI
Parameter
0
protocol
management
1 = Setpoint failure
r2043.0
IF1 PD PZD state
r2043.2
1 = Fieldbus operation
3
4
Field bus USS PZD
0...16
Field bus address
Field bus USS PKW
p2022 (2)
0...31
0...127
p2021 (0)
p2023 (127)
USS
PZD IF HW assign
p8839[1] (1)
<3>
2
1
PZD IF HW assign
0
p8839[0] (1)
<2>
2
1
0
Monitoring and
diagnostics
<7>
<1>
Cyclic telegrams
from the master
T
0
<4>
t
PB status
r2054
PB diag standard
r2055[0...2]
Field bus error
r2029[0...7]
Diagnostic parameters
5
fp_2410_13_eng.vsd
17.08.18 V01.05.00
PROFIdrive sampling time
Fieldbus USS DO_no
1...62
p2035 (2)
PROFINET address
PN Name of Station
r61000[0...239]
PROFINET
PN IP of Station
r61001[0...3]
[2485]
PZD
[2487]
IF2
[2489]
[2460]
[2470]
PZD
[2472]
IF1
[2481]
[2483]
F08501 "PROFINET/COMM BOARD:
Setpoint timeout"
A01920 "PROFIBUS: Interruption cyclic connection"
IF1 PD fault delay
0...100 [s]
p2044 (0)
T
0
S Q
F01910 "Fieldbus: Setpoint timeout"
R Q
A01900 "PB/PN: Configuration telegram error"
A01902 "PB/PN: Clock cycle synchronous operation parameterization
not permissible"
r2075 IF1 diag offs recv
r2076 IF1 diag offs send
6
7
Function diagram
SINAMICS DCM
DC_CTRL
8
- 2410 -