Descargar Imprimir esta página

Siemens SINAMICS DCM Manual página 780

Ocultar thumbs Ver también para SINAMICS DCM:

Publicidad

m_set lim p sig s
p50642[0...3]
[0](r52002)
[1](r52002)
[3100.8]
[2](r52002)
[3](r52002)
m_set_factor
-300.00...300.00 [%]
p50320[D] (100.00)
m_set sig s
p50644[C]
(r52206)
[3130.8]
m_setp bef lim [%]
r52198
m_set factor sig s
p50322[C]
(1)
m_set lim n sig s
p50643[0...3]
[0](r52184)
[1](r52185)
[3135.4]
[2](r52186)
[3](r52187)
Add_set_factor
-300.00...300.00 [%]
p50321[D] (100.00)
Add_set sig s
p50645[C]
(0)
Add_set fac sig s
p50323[C]
(1)
1
2
DO: DC_CTRL
Setpoint channel - Setpoint preprocessing
-1
-1
-1
-1
Red factor
Minimum
0.00...100.00 [%]
m_set up lim eff [%]
p51608[D] (15.00)
r52196
+
+
m_set low lim eff [%]
r52197
Red sig s
p51607[C]
Maximum
Set before reduc [%]
3
4
m_set neg def 0 [%]
r52184
[3135.2]
m_set neg def 1 [%]
r52185
m_set neg def 2 [%]
n_set bef RFG disp [rpm]
r52186
m_set neg def 3 [%]
r52187
RFG set sig s
0
Set after reduc [%]
p50635[C]
r52194
(r52194)
[3135.6]
[3135.5]
1
(1)
r52195
5
6
fp_3135_13_eng.vsd
26.10.18 V01.05.00
4000 μs
[1721]
n_ref
6.00...210000.00 [rpm]
p2000 (210000.00)
r50028
0 %
0 0
Outp to RFG [%]
0 1
r52193
-1
1 0
[3151.4]
1 1
Dir rot enab
Enab n dir r sig s
r53170.4
p50671[C]
0 = Enable
(1)
1 = No enable
Enab p dir r sig s
p50672[C]
(1)
7
8
Function diagram
- 3135 -
SINAMICS DCM

Publicidad