Signal sources for ZSW1 fo telegrams 1, 3, 4, 20, 352
Signal
Meaning
ZSW1.0
1 = Ready to switch on
ZSW1.1
1 = Ready
ZSW1.2
1 = Operation enabled
ZSW1.3
1 = Fault effective
ZSW1.4
1 = No coasting active (OFF2 inactive)
ZSW1.5
1 = No Quick Stop active (OFF3 inactive)
ZSW1.6
1 = Switching on inhibited active
ZSW1.7
1 = Alarm effective
ZSW1.8
1 = Speed setpoint - actual value deviation within tolerance t_off
ZSW1.9
1 = Control request
ZSW1.10
1 = f or n comparison value reached or exceeded
1 = M limit not reached
ZSW1.11
1 = I or M limit not reached
1 = Holding brake open
ZSW1.12
Reserved (always value 0)
ZSW1.13
1 = No warning overtemperature motor
1 = Motor rotates forwards (n_act >= 0)
ZSW1.14
0 = Motor rotates backwards (n_act < 0)
1 = No warning thermal overload power unit
ZSW1.15
1 = Command data set CDS effective bit 0
<1> For telegram 20.
<2> ZSW1 is formed via binector-connector converter (BI: p2080[0...15], inversion: p2088[0].0...15).
1
2
DO: DC_CTRL
PROFIdrive - ZSW1 status word interconnection
p2080[0] = r0899.0
p2080[1] = r0899.1
p2080[2] = r0899.2
p2080[3] = r2139.3
p2080[4] = r0899.4
p2080[5] = r0899.5
p2080[6] = r0899.6
p2080[7] = r2139.7
p2080[8] = r2197.7
p2080[9] = r0899.9
<3>
p2080[10] = r2199.1
p2080[11] = r1407.7
p2080[11] = r0056.13
<1>
p2080[12] = r0899.12
<1>
p2080[13] = r2135.14
p2080[14] = r2197.3
p2080[15] = r2135.15
p2080[15] = r0836.0
<1>
3
4
<2>
Interconnection
Function diagram
Inverted
parameter
[2585.7]
[2585.7]
[2585.7]
[2548.7]
[2585.7]
[2585.7]
[2585.7]
[2548.7]
[2534.6]
[2585.7]
[2537.6]
[2585.7]
[2548.7]
[2534.6]
[2548.7]
[8560.7]
<3> The drive object is ready for acceptance.
5
6
fp_2452_13_eng.vsd
16.11.18 V01.05.00
PROFIdrive sampling time
7
8
Function diagram
- 2452 -
SINAMICS DCM