Interconnection of STW BOP (r0019)
Signal
Meaning
1 = ON
STW BOP.0
0 = OFF (OFF1)
1 = No coast down
STW BOP.1
0 = Coast down (OFF2)
1 = No quick stop
STW BOP.2
0 = Quick stop (OFF3)
STW BOP.3
Reserved
STW BOP.4
Reserved
STW BOP.5
Reserved
STW BOP.6
Reserved
STW BOP.7
= Acknowledge fault
STW BOP.8
Reserved
STW BOP.9
Reserved
STW BOP.10
Reserved
STW BOP.11
Reserved
STW BOP.12
Reserved
STW BOP.13
1 = Motorized potentiometer, raise
STW BOP.14
1 = Motorized potentiometer, lower
STW BOP.15
Reserved
<1> The BICO interconnection represents an example that can be be changed by the user.
<2> Only for CU_DC (SINAMICS DCM).
1
2
DO: CU_DC, CU_DCP
Basic Operator Panel 20 (BOP20) - Control word interconnection
<1>
Interconnection
parameter
p0840[0] = r0019.0
p0844[0] = r0019.1
p0848[0] = r0019.2
p2102[0] = r0019.7
<2>
p1035[0] = r0019.13
p1036[0] = r0019.14
<2>
3
4
-
-
-
-
-
-
-
-
-
-
5
6
fp_9912_70_eng.vsd
20.08.18 V01.05.00
PROFIdrive sampling time
7
8
Function diagram
- 9912 -
SINAMICS DCM/DCP