DO NOT use CO2 gas regulator/flow for Pure Argon or Argon/Mixed shielding gas.
Obtain gas cylinder and chain to running gear, wall, or other stationary support so cylinder
cannot fall and break off valve.
1. Cap
2. Cylinder Valve: Remove cap, stand to side of valve, and open valve slightly. Gas flow blows
dust and dirt from valve. Close valve.
3. Cylinder
4. Regulator/Flowmeter: Install so face is vertical.
5. Regulator/Flowmeter.
6. Gas flow bar.
7. Flow Adjust.
8. Gas hose connection.
9. Single Phase - 220V power cable with plug. Flow rate should be set when gas is flowing
through welding power source and welding gun. Open pressure assembly so that wire will not
feed. Press gun trigger to start gas flow.
5. Adjustment
5.1.
Appearance
1. JOG - Check the wire after set up the loading wire feeder.
2. PURGE - Hold down to check out the gas after connecting the gas pipe from the wire feeder to
the cylinder and after completing the connection of the welding gun.
3. SYN/MAN WIRE SIZE - Pressing to choose SYNERGY - SYN or MANUAL - MAN function.
SYNERGY - SYN function: Just need adjust the button to increase or degrease, the wire speed
and welding voltage will change respectively. Pressing to choose Syn function for each wire
size 0.8, 0.9, 1.0 mm. After choosing, LED - M/MIN indicate wire speed will turn on.
MANUAL - MAN function: Welding voltage, wire speed will be adjusted seperately. Press the
button one time to select welding voltage and welding current seperate adjustment. This
function can not work in MMA of LIFT-ARC TIG mode.
4. PROCESS - Press the button to choose the welding method.