Descargar Imprimir esta página

Moretti Forni T Serie Manual Instrucciones página 68

Ocultar thumbs Ver también para T Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

After installing, the oven reaches set
point or fails to keep the temperature
After some time, the oven stops to
maintain the temperature during
cooking
Burner fan malfunction
Alarm view ALL1:
-
the baking fan stops
-
maximum safety temperature
exceeded.
-
overtemperature in motor
compartment
Thermocouples alarm (ALL2)
Signal Electric panel over
temperature (ALL3)
Wrong gas supply pressure
Reset for the wrong gas type
Economy mode included
Burner head clogged by dust
Burner fan electrical connections
inefficient
Burner fan failure
Excessive load on the baking fan
motor
Electronic control anomaly.
Safety thermostat damaged
Cooling fan ineffective
Thermal intervention integrated into
the cooling fan
No signal from the thermocouple
to the power tab
Thermocouple damaged
Rear cooling fan ineffectiveness
UK/23
Ensure that gas and supply pressure
are set as shown in TAB. 1 the
instruction manual (for your country)
Ensure that the oven gas supply
pressure and the outgoing pressure
from the gas valve is 0 mbar.
Disable the economy mode
Clean the burner head, remove the
cause of the dust inside and clean the
air filter
Ensure that all connections Burner
fan are effective and that no cables
have been damaged
Replace the fan
Make sure that the motor shaft can
turn freely and if necessary, remove
the cause of the abnormal load
Solve the anomaly and after cooling,
reset the safety thermostat button
Replace safety thermostat
Make sure that the cooling fan is
operating correctly and that the
cooling is effective; the intake vents
for the cooling air must be clean and
there should be no intake of warm air.
Wait until the thermal breaker is
automatically restored and check why
it tripped.
Ensure that the connection is
effective,
and the compensating cable is
intact.
Replace thermocouple
Make sure that the cooling fan is
operating correctly, taking air from
the inside of the electric panel and
that the cooling is effective; the
intake vents for the cooling air must
be clean and there should be no
intake of warm air.

Publicidad

loading