Burner fan malfunction
Max. safety temperature exceeded
alarm
Fan Alarm stopped
Failure to start cooking fan motor
Belt stopped alarm
Irregular electronic control
Electrical panel overtemperature
signal
If Start is pressed immediately the
alarm buzzes:
Burner Block
The flame is unstable and reddish,
sometimes the alarm buzzes:
Flame Off
Burner fan electrical connections
inefficient
Burner fan failure
Electronic control failure.
Safety thermostat damaged
Excessive load on the cooking fan
motor
Ineffectiveness of the cooking fan
cooling motor
Damaged condenser
Ineffective speed check of belt
rotation
Gear motor failure
Wrong data transfer
Electronic board damaged
Keyboard fault
Rear cooling fan inefficient
Electrical panel cooling fan
inefficient (where fitted)
The Reset signal from the electronic
board relay SC1 fails to reach the CF
control flame
SCI electronic board damaged
CF Flame control damaged
Gas valve output pressure
unregulated
UK/26
Ensure that all connections Burner
fan are effective and that no cables
have been damaged
Replace the fan
Resolve failure and after cooling,
reset safety thermostat button
Replace safety thermostat
Ensure that the transmission shaft
turns loosely and remove the cause of
the irregular load if necessary
Ensure that the rear air inlet is open
and that the fan on the motor is
effective
Replace the condenser
Reset or replace sensor
Replace the gear motor
Run general Reset and then restore
the software parameters for the power
gas
Replace the electronic board
Replace keyboard
Make sure that the ventilation from
the rear cooling fan is efficient and
that it reaches the electrical panel.
Check the efficiency of the electrical
panel cooling fan (where fitted)
Ensure that all connections from the
SC1 circuit board to the CF flame
control are effective and that there are
no damaged cables
Replace the SCI electronic board
Replace the CF flame control
Check that the output pressure from
the valve is 0 otherwise adjust; if it
fails to adjust, replace the valve