43 9.3.3 Filling With Refrigerant And Fresh Oil - Bosch ACS 810 Manual Original

Ocultar thumbs Ver también para ACS 810:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 97
en
54 | ACS 810 | Operation
9.3.2
Vacuum phase
i
Make sure recovery has been performed before
generating the vacuum.
i
The vacuum phase is not started if there is
pressure in the vehicle air conditioning system. A
corresponding fault message is displayed on the
screen.
!
Follow the additional ACS 810 menu prompting.
<Vacuum> key
1. Connect the HP and LP service hoses to the vehicle
air conditioning system.
2. Open the valves on both service hoses.
3. Open the HP and LP valves on the display and
control panel.
4. Call up the start screen.
5. Press the <Vacuum> key.
6. Enter duration of vacuum generation with <0 – 9>
and confirm with E.
 ACS 810 performs the vacuum phase.
i
After the vacuum phase, the time is started for the
pressure monitoring (leak test). After this time has
elapsed, the vehicle air conditioning system is tested
for leaks. The result from this leak test is displayed
on the screen.
7. Close the HP and LP valves on the display and con-
trol panel.
8. Close the valves on both service hoses.
i
After the vacuum phase, you must confirm whether
the stored vehicle data should be deleted.
i
Return with <Stop>.
|
S P00 D00 006
2019-02-26
9.3.3
Filling with refrigerant and fresh oil
i
Fresh oil can only be added to a vehicle air
conditioning system under a vacuum. A vacuum must
be generated prior to the filling process.
i
If pressure is detected in the air conditioning system
during the filling process, a recovery must be
conducted before the filling can be continued.
i
Fresh oil can only be added in conjunction with
R134a refrigerant.
!
Always follow the vehicle manufacturer's instructions
before altering the oil quantity.
!
Ensure that the valves on the control panel are
closed, as internal components will otherwise be
damaged and lead to impaired functionality of the
machine.
!
Filling should, if possible, only occur via the high
pressure connection. For systems that have only a
low-pressure connection, at least 10 minutes must
pass after filling before the vehicle air conditioning
system can be switched on again.
!
In oder to carry out the filling process correctly,
ensure that the there are at least 2 kg more
refrigerant in the internal refrigerant cylinder than
would be necessary according to the filling quantity.
The software does not accept any lower values.
!
The quantity of fresh oil cannot be given and is
instead filled in a time-controlled manner. We
recommend recording the oil levels in the fresh and
used oil bottles before A/C service and noting the
required quantity of fresh oil on the fresh oil bottle.
Robert Bosch GmbH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Acs 611Acs 611-ukAcs 611-gAcs 611-icAcs 511Acs 652

Tabla de contenido