<Fill> key
!
Follow the additional ACS 810 menu prompting.
1. Connect the HP and LP service hoses to the vehicle
air conditioning system.
2. Open the valves on both service hoses.
3. Open the HP and LP valves on the display and
control panel.
4. Call up the start screen.
5. Press <Fill>.
CHARGING OIL?
1 - YES
2 - NO
6. Select <1> or <2> and confirm with E.
SET REFRIGERANT CHARGE
7. Enter refrigerant quantity (R134a) with <0 – 9> and
confirm with E.
CHARGING OIL?
8. If
was answered with "
the <MENU> key to open the solenoid valve for oil
filling and to start the filling process.
!
Monitor the oil level in the fresh oil bottle during the
filling process and do not leave ACS 810unattended.
9. As soon as the required quantity of fresh oil has
been filled, stop the filling process by pressing the
<MENU> key again (solenoid valve closes).
10. Start the refrigerant filling process by pressing E.
ACS 810 will fill the vehicle air conditioning
system with R134a refrigerant.
i
After the filling process is concluded, the quantity of
refrigerant filled is shown in the display.
i
The quantity of filled refrigerant displayed can be
deleted if required by pressing <MENU>. The filled
refrigerant quantity can then be entered manually
using the numerical keys.
"
Filling phase stopped.
i
Print with E
i
Return with <Stop>.
Robert Bosch GmbH
9.4
!
1. Call up start screen.
2. Press <MENU>.
3. Select <TANK RECYCLING> with o u and confirm
i
i
is displayed.
YES
", press
Operation | ACS 810 | 55
Tank recycling
Observe the ACS 810 menu prompting.
with E.
The processing duration is limited to 60 minutes
and stops automatically after the internal circuit has
been drained.
Return with <Stop>.