9.3.1
Recovery
i
During the recovery phase, ACS 810 automatically
empties the service hoses and separates the
extracted oil from the refrigerant which flows into
the used oil bottle.
i
The pressure in the vehicle air conditioning system
must be checked prior to and during the recovery
phase.
i
It is recommended to let the air conditioning system
run for a few minutes before the recovery. This will
allow a larger amount of refrigerant to be extracted.
Turn off the air conditioning system before starting
recovery.
!
Follow the additional ACS 810 menu prompting.
<Recovery> key
1. Connect the HP and LP service hoses to the vehicle
air conditioning system.
2. Open the valves on both service hoses.
3. Open the HP and LP valves on the display and
control panel.
4. Call up the start screen.
5. Press <Recovery>.
 ACS 810 performs a self-cleaning process.
i
Self-cleaning is necessary when the weight of the
extracted refrigerant must be precisely determined.
The self-cleaning can be skipped by pressing <MENU>.
 The recovery is started automatically after the
self-cleaning.
i
The self-cleaning is stopped automatically when
the pressure in the vehicle air conditioning system
reaches 0.
Robert Bosch GmbH
Operation | ACS 810 | 53
i
Multiple oil draining cycles are conducted to
optimize the recovery. After the last cycle, ACS 810
tests within a set waiting time whether any increase
in pressure can be detected. In the event of a
pressure increase, the recovery is restarted.
 The amount of refrigerant extracted is displayed
on the screen after the recovery.
6. Close the HP and LP valves on the display and con-
trol panel.
7. Close the valves on both service hoses.
i
After the recovery phase, you must confirm whether
the stored vehicle data should be deleted.
i
After the recovery, the extracted oil quantity can
be entered using the numerical keys and printed by
pressing E .
i
Return with <Stop>.