POWR
STARTER MOTOR
6. Inspect:
Armature coil continuity
Out of specification → Replace.
Armature coil continuity:
Commutator segments 1
Segment - Laminations 2
Segment - Armature shaft
Brush holder inspection
1. Measure:
Brush length a
Out of specification → Replace.
Min. brush length:
6.5 mm (0.26 in)
2. Check:
Brush holder continuity
Out of specification → Replace.
Brush holder continuity:
Brush holder - Base
Starter motor front cover inspection
1. Inspect:
Starter motor front cover bushing
Damage/wear → Replace the starter
motor front cover.
5-30
E
Continuity
No continuity
No continuity
No continuity