ELEC
INDICATION SYSTEM
Fuel level switch
1. Check:
Fuel level switch
Not operating → Replace the multi-
function meter.
Checking steps:
Supply 7 - 12 V to the white four-pin
connector (+: red, –: black) with a
remote battery or an AC adapter.
Disconnect the green two-pin connec-
tor (white/blue and black leads).
Connect the white/blue and black ter-
minals with a jumper lead 1.
Connect the green and red terminals
with a jumper lead 2.
NOTE:
If the jumper lead is installed for more
than 30 seconds, the display will auto-
matically turn off.
Check the fuel level segments is full
indicated.
Remove the jumper lead from the
green two-pin connector.
Disconnect the jumper lead 2 and
then connect it to green and red ter-
minal again.
Make sure the fuel low level segment
3, fuel level warning indicator 4,
"
" message 5 and "WARNING"
lamp 6 blinks and the buzzer sounds
intermittently.
7-24
E