ELEC
W/R
W/G
IGNITION SYSTEM
L
B/R
L B/R Br
Br
B
B
W/B
W/G
W/B
W/R B
B
CHARGE COIL
1. Measure:
Charge coil resistance
Out of specification → Replace.
Charge coil resistance:
Black/Red (B/R) – Brown (Br)
172.0 ~ 258.0 Ω at 20 ˚C (68 ˚F)
Black/Red (B/R) – Blue (L)
656.0 ~ 984.0 Ω at 20 ˚C (68 ˚F)
PULSER COIL
1. Measure:
Pulser coil resistance
Out of specification → Replace.
Pulser coil resistance:
White/Red (W/R) – Black (B)
White/Black (W/B) – Black (B)
White/Green (W/G) – Black (B)
248.0 ~ 372.0 Ω at 20 ˚C (68 ˚F)
THERMO SWITCH
1. Measure:
Thermo switch continuity
Out of specification → Replace.
Thermo switch continuity
temperature:
Pink (P) – Black (B)
a 90 ~ 96 ˚C (194 ~ 205 ˚F)
b 76 ~ 90 ˚C (169 ~ 194 ˚F)
1 No continuity
2 Continuity
Measurement steps:
Suspend the thermostat in a container
filled with water.
Place a thermometer in the water.
Slowly heat the water.
Measure the continuity when the spec-
ified temperature is reached.
7-11
E
Å Temperature
ı Time