2. Check:
Relay operation
Faulty → Replace.
Checking steps:
Connect the tester between the starter
relay terminals as shown.
Tester positive lead 1 →
Starter relay terminal
Tester negative lead 2 →
Starter relay terminal
Check that there is no continuity
between the starter relay terminals.
Connect
between the starter relay terminals.
Tester positive lead 1 →
Starter relay terminal
Tester negative lead 2 →
Starter relay terminal
Battery positive terminal →
Brown lead terminal 3
Battery negative terminal →
Black lead terminal 4
Check that there is continuity between
the starter relay terminals.