ADJUSTMENTS
WARNING: Before it is put into service, the system must be tested to check the operating
conditions of every single component and identify any malfunctions . In this stage, it is important
to check that all health and safety requirements have been complied with in full .
To test the system, make the following checks.
1) Turn on the water supply tap and make sure that the connection is watertight.
2) Turn on the master switch to check the electrical connection.
3) Make sure that the mains voltage is the same as that of the appliance and, if necessary, carry out the
conversion (see page 9).
4) Check the water pressure and adjust if necessary (see page 10).
5) Check that the safety device is operating correctly.
6) Carry out a cooking cycle without food to ensure that the appliance is operating correctly.
After testing, if necessary instruct the user in all the skills necessary for putting the appliance into ope-
ration in conditions of safety, in accordance with legal requirements.
WARNING: Before making any type of adjustment, activate all the safety devices provided
and decide whether staff at work and those in the vicinity should be informed .
In particular, turn off the water supply tap, cut off the electricity supply using the master switch and
prevent access to all devices that might cause unexpected health and safety hazards if turned on .
WARNING: Adjustments must be carried out by authorised, qualified staff, in accordance
with the relevant legal requirements .
To carry out this operation, proceed as follows.
1) Undo the screws to remove the side panel (A).
2) Turn on the water supply tap (B).
3) Unscrew the ring nut (C).
4) Turn the cooking chamber water intake screw (D) to bring the pressure reading on the pressure
gauge (E) to 1 bar.
If the water pressure is too low, install a device to increase the pressure .
5) Retighten the ring nut (C).
6) Replace the panel (A) and screw the screws back into place.
7) Turn the water supply tap (B) back off when the operation is complete.
3326461_GB_inst_rev.1
TESTING OF THE APPLIANCE
ADJUSTMENTS
INSTRUCTIONS AND WARNINGS FOR ADJUSTMENTS
ADJUSTING THE WATER PRESSURE
E
C
D
A
B
ENGLISH
13

Publicidad

loading

Este manual también es adecuado para:

Bx61erBx101eBx101erBx82eBx122e