9.2.1 INFORMATION DISPlAyED AT START-UP
Upon start-up, the information below is displayed in sequence:
FhASE
wait
1
2
3
WARNING!
• Along with the above mentioned signals, an alarm message to change the pump oil is displayed upon
start-up if the maximum number of cycles admissible has been reached (see next § 9.2.3).
9.2.2 DISPlAy OF ThE NUMBER OF CyClES PERFORMED BEFORE ThE OIl MUST BE REPlACED
The number of cycles performed since the last oil change is displayed upon each start-up.
The number of cycles performed is graphically represented by the number of LEDs turned on: a number of LEDs propor-
tional to the number of cycles conducted lights up according to the model of the installed pump.
If all the LEDs light up, this means the maximum number of cycles has been reached for the pump oil to be replaced and
an "oil change alarm" is displayed.
The cycles must be reset by an authorised after-sales centre once the pump oil has been replaced.
To recall the exact number of cycles performed by the machine, turn on the machine
and press the "PUMP" and "STOP" buttons together.
The lower display will show the number of cycles performed since the last reset.
9.2.3 DISPlAy OF ThE SERIAl NUMBER
To recall the serial number of the machine, press the "PUMP" and "STOP" buttons together.
Rev. 05 - 04/2018 - Cod. 1500458 - Instruction manual for vacuum chamber packaging machines with digital control panel "Serie Bright"
DISPlAy
MESSAGE ON ThE DISPlAy
lEDs: All ON
upper lED: WAIT
lower: SOFTWARE VERSION: NR.02
lEDs: NUMBER OF CyClES PERFORMED BEFORE ThE OIl MUST
BE REPlACED (E.g:4 lEDS OUT OF 12 = 33% OF ThE CYClES
PERFORMED)
upper lED: SET – UP
lower: OPTIONS AVAIlABlE: SOFTAIR, DATE ClOCK, ETC.
lEDs: NUMBER OF CyClES PERFORMED BEFORE ThE OIl MUST
BE REPlACED (E.g:4 lEDS OUT OF 12 = 33% OF ThE CYClES
PERFORMED)
upper lED: SET – UP
lower: VAlUES OF ACTIVE FUNCTIONS
OPERATION
43