Operation; Control Panel - Orved Bright Serie Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

9. OPERATION

9.1 CONTROl PANEl

POS. COMPONENT
Main switch
1
Vacuum gauge
2
Cursor key (UP)
3
Programming Key
4
(PROG)
Cursor key (DOWN)
5
Key to select
6
functions (SEl)
Key to activate
7
pump and jar
functions (PUMP)
STOP Key
8
lower and upper 6+6
9
digit display
10
6 upper lEDs and 6
11
lower lEDs
12
Rev. 05 - 04/2018 - Cod. 1500458 - Instruction manual for vacuum chamber packaging machines with digital control panel "Serie Bright"
3
2
4
5
FUNCTION
• Switches the machine "ON/OFF"
• Emergency stop.
• Indicates the vacuum in the chamber.
• Scrolls through the programs.
• Changes the values of the functions.
• Scrolls through the languages of the display.
• Pressed together with "STOP" upon start-up, it allows to reset stored programs and restores the factory
settings.
• Allows to access the programming of a function.
• Confirms the value or function set.
• Activates the sensor calibration function if pressed upon start-up.
• Pressed for 4 seconds, allows storage of custom user program name.
• Pressed while selecting the deaeration cycle with vacuum bags, allows the programming of sealing time.
• Scrolls through the programs.
• Changes the values of the functions.
• Scrolls through the languages of the display.
• Scrolls through the internal functions of a program.
• Activates the programming of the display language if pressed upon start-up.
• Allows to move to the next function in advance.
• Activates sealing in the packaging of external channelled bags.
• Selection of container vacuum cycles.
• Pressed for 4 seconds, it activates the continuous pump cycle in three-phase versions with 60 and
100 m
/h pump.
3
• Pressed together with the "STOP" key, it allows to display the machine's serial number.
• Pressed upon start-up together with the "STOP" key, it allows to display the number of cycles performed
before the oil must be replaced.
• Interrupts the cycle in progress
• If pressed for 4 seconds, it activates/deactivates the buzzer.
• Pressed upon start-up together with the "PUMP" key, it allows to display the number of cycles performed
before the oil must be replaced.
• Pressed together with the "PUMP" key, it allows to display the machine's serial number.
• Pressed together with the"UP" key upon start-up, it allows to reset stored programs and restores the factory
settings.
• They display the active program.
• They display the active function and the relative value set, together with the numerical progress of the set value.
• They display alarm warnings.
• They display the machine's serial number.
• They display the number of cycles performed before the oil must be replaced.
• They display the progress of the current cycle.
• They display alarms.
• They provide a graphical indication of the number of cycles performed before the oil must be replaced.
11
9
12
10
OPERATION
6
1
8
7
41

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bright 315Bright 12Bright 16Bright 18

Tabla de contenido