Replacing The Cover Gasket - Orved Bright Serie Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

11.10 REPlACING ThE COVER GASKET

1) Open the Plexiglas cover as far as possible (95°) (Fig. 1).
2) Remove the old gasket by sliding it out of its seat. Clean the seat of the
gasket with neutral detergent (Fig. 2).
3) Starting at the centre back of the seat in the cover (on the side of the
hinges), fit the gasket in all the way round (Fig. 3) making sure to do
the following:
a) Make the two cuts in the gasket in a neat and precise manner.
b) Check the lip of the gasket faces outwards.
c) Do not stretch the gasket when fitting it in.
4) Run a cycle with the vacuum set at maximum. When the maximum pres-
sure is reached, turn off the machine at the main switch: the chamber
will be pressurized with the cover down. To check successful operation,
wait for 5 minutes with the cover closed and the chamber pressurized.
Rev. 05 - 04/2018 - Cod. 1500458 - Instruction manual for vacuum chamber packaging machines with digital control panel "Serie Bright"
MAINTENANCE AND TEChNICAl SUPPORT
Fig. 1
Fig. 1
Fig. 2
Fig. 2
Fig. 3
77

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bright 315Bright 12Bright 16Bright 18

Tabla de contenido