IMpORTANT: The distance between the Railok 90 Shuttle and the frontal connection on the Full Body
Harness is limited by the Shuttle's Energy Absorber and attached Carabiner. Never add additional
Connectors or Lanyards that may increase this distance.
Step 4.
Ascending and Descend the structure in the following manner:
A.
Ascent:
To ascend, climb up normally on the Ladder or Ladder Rail Rungs at a steady rate. The
Railok 90 Shuttle will follow along on the Rail.
B.
Descent:
Railok 90 Shuttle will follow along on the Rail. If the Shuttle locks on the Rail, move upward slightly
to release the Shuttle and then continue descending.
ReST PLATFoRm InSTALLATIon & oPeRATIon: A Rest Platform (RP) can be installed on the Railok 90
Rigid Rail Safety System where added surface area is needed for rest or work (see Parts Table RP):
Installation:
The Rest Platform attaches to the structure with two Mounting Brackets with the Rail Clamps
removed (as illustrated in Parts Table RP). For each Rail Bracket and Rest Platform Mounting Bracket:
1.
Assemble the Rest Platform as shown in Parts Table RP. Torque all fasteners to the indicated values.
2.
Remove the appropriate M16 Fasteners and Rail Clamp from the Rail Bracket.
3.
Remove the M16 bolts from the Rest Platform Mounting Brackets.
4.
Align the open hole on the Rail Bracket with the hole in the Rest Platform Mounting Bracket and insert the
M16 bolt supplied with the Rest Platform.
5.
Torque M16 Hex Nuts and Jam Nuts to the torque values identified in Parts Table RP.
operation:
The hinged Rest Platform Floor can be locked in the upright position when the Rest Platform is not
in use (as illustrated in Parts Table RP):
1.
To Lock the Rest Platform Floor in the upright Position:
Rest Arm. Rotate the Locking Latch counter-clockwise to secure the Floor in the upright position.
2.
To unlock and Position the Rest Platform Floor for use:
swing the Floor downward until it rests on the Rest Platform Base.
AnTI-CLImB DooR InSTALLATIon & oPeRATIon: An Anti-Climb Door (ACD) can be installed on the
Railok 90 Rigid Rail Safety System and Pad Locked shut to prevent unauthorized climbing (See Parts Table ACD).
Installation:
The Anti-Climb Door attaches to the structure with three Mounting Brackets with the Rail
Clamps removed (as illustrated in Parts Table ACD):
1.
Loosely attach three Rail Brackets, 3 ft. (91.4 cm) apart, to the ladder/structure at the approximate
location where the Anti-Climb Door should block access to the structure and Railok 90 Rail.
2.
Remove Rail Clamps and associated fasteners from the clamp end of the Rail Brackets.
3.
Attach an L-Bracket to the clamp end of each Rail Bracket with a 1-1/2 in. Bolt, two Fender Washers, a
Lock Washer, and a Nut.
4.
Attach the three v-Brackets to the Door with the provided 1 in. Carriage Bolts using the pre-drilled
mounting holes. Brackets should be space approximately 3 ft. (91.4 cm) apart.
5.
Lift the Door into place on the ladder/structure so the v-Brackets on the door align with the L-Brackets on
the ladder/structure.
6.
Starting from the top of the door, secure each v-Bracket to it's adjoining L-Bracket with the provided
fasteners (1-1/2 in. Bolts, Lock Washers, and Nuts).
NOTE: The Rail Brackets may need to be moved up or down on the ladder/structure for proper vertical
alignment of V-Brackets and L-Brackets. The Anit-Climb Door should surround the ladder/structure
when closed. There are multiple holes in the V-Brackets and L-Brackets to allow horizontal positioning
of the door.
7.
Once the door is positioned properly on the ladder/structure, tighten the fasteners that secure the Rail
Brackets to the ladder/structure.
8.
Align and secure the Door Lock Bracket assembly to two Ladder Rungs so the attached U-Bolt protrudes
through either of the vertical slots in the door face when the door is closed. For proper horizontal
adjustment, slide the Door Lock Mounting Plates left or right on the Ladder Rung. For proper vertical
adjustment, reposition the U-Bolt in different holes in the Door Lock Bracket.
operation:
To prevent unauthorized use of the Railok 90 Rigid Rail Safety System, swing the Anti-Climb Door
fully closed and lock a Pad Lock through the U-Bolt extending through the door face.
To descend, climb normally down the Ladder or Ladder Rail Rungs at a steady rate. The
Swing the Floor upward until it contacts the
Rotate the Locking Latch clockwise and then