Ground; General Information On Ground Connections; Metal Pipe With Fixed Flanges - ABB ProcessMaster Instrucciónes De Puesta En Marcha

Ocultar thumbs Ver también para ProcessMaster:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 177
Mounting
4.6

Ground

4.6.1

General information on ground connections

Observe the following items when grounding the device:
For plastic pipes or pipes with insulating lining, the ground is provided by the grounding plate
or grounding electrodes.
When stray potentials are present, install a grounding plate upstream and downstream of the
flowmeter sensor.
For measurement-related reasons, the potentials in the station ground and in the pipeline
should be identical.
An additional ground on the terminals is not required.
Important (Notice)
If the flowmeter sensor is installed in plastic or earthenware pipelines, or in pipelines with an
insulating lining, transient current may flow through the grounding electrode in special cases.
In the long term, this may destroy the sensor, since the ground electrode will in turn degrade
electrochemically. In these special cases, the connection to the ground must be performed
using grounding plates. Install a grounding plate upstream and downstream of the device in
this case.
4.6.2

Metal pipe with fixed flanges

Use a copper wire (at least 2.5 mm² (14 AWG)) to establish the ground connection between the
sensor (1), the pipeline flanges and an appropriate grounding point.
Fig. 20: Metal pipe, without liner
22 - EN
Flange design
FEX300, FEX500
Wafer flange design
CI/FEX300/FEX500-X1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

HygienicmasterFex300Fex500

Tabla de contenido