7 HANDLING
The packaging is marked with warning symbols that indicate
the precautions to be taken when handling the appliance to
avoid damage. The appliance must only be handledusing su-
itable equipment. If lifting equipment is used, such as forklift
trucks or similar, make sure that the appliance is in a stable
position.
8 UNPACKING
Check the state of the packaging and in the event of damage,
ask the delivery person to inspect the goods.
• Remove the packaging.
•
nels. Use a suitable solvent to remove any residual adhesive
from the panels.
9 POSITIONING
• The dimensions of the appliance and the position of the con-
nections are shown in the installation diagram at the begin-
ning of the manual.
• The appliance can be installed singly or in combination with
other appliances in the same product range.
• The appliance is not suitable for integrated installation.
• Position the appliance at least 10 cm from the surrounding
walls. If the appliance is placed very close to partition walls,
kitchen cupboards, decorating elements, etc., make sure that
these are made of non-combustible materials. If not, they
should be covered with suitable non-combustible thermally
vention regulations.
• Level the appliance by means of the height-adjustable feet
• The countertop appliance weighing less than 40kg, where
vided.
APPLIANCE ASSEMBLY WITH BASE, BRIDGE, AND CAN-
TILEVER SOLUTIONS
Follow the instructions provided with the type of support utili-
zed.
FIXING THE APPLIANCE TO THE FLOOR
JOINING APPLIANCES TOGETHER IN LINE
• Remove the control panels (A).
• Place the appliances side by side and adjust the tops to the
same height (C).
• Join the appliances in points (B) and (D) using the screws
supplied.
• Loosen the 2 front screws (E), turn the plate (F) to hook on
the screw on the adjacent appliance.
• Tighten the screws (E).
10 FUMES EXHAUST SYSTEM
Provide a fumes exhaust system based on the "Type" of ap-
pliance.The "Type" is stated on the appliance dataplate.
APPLIANCE TYPE "A1"
• Position the "A1" type appliance below an extractor hood to
ensure smoke and fumes generated by cooking are removed.
APPLIANCE TYPE "B21"
• Position the "B21" type appliance below an extractor hood.
6
APPLIANCE TYPE "B11"
•
from the appliance manufacturer. Follow the assembly in-
•
stant to 300°C.
•
must not exceed 3 metres.
11 CONNECTIONS
The position and dimensions of connections are given in the
installation diagram at the start of this manual.
-
CONNECTION TO THE GAS SUPPLY
Check the compatibility of the gas supply. Check the details
given on the decals on the packing and on the appliance. If
necessary, convert the appliance to the type of gas utilized.
Follow the instructions in the next paragraph "Conversion to a
On top appliances a rear connection is also available. Remove
the plug present and screw it tightly onto the front connector.
•
the appliance in an easily accessible position.
• Do not use connection pipes having a diameter smaller than
that of the appliance's gas connector.
• Once the appliance has been installed, check for leaks at the
connection points.
-
ELECTRICAL CONNECTIONS
Check that the appliance is designed to operate at the voltage
and frequency of the power supply present on site. Check the
details given on the appliance data plate.
-
If used, the symbol
CAUTION - HAZARDOUS VOLTAGE.
• Install an adequately rated omnipolar circuit-breaker upline
of the appliance in an easily accessible point, in compliance
with installation regulations; the circuit breaker must guaran-
tee immediate omnipolar disconnection from the mains, with
a minimum contact opening that allows complete disconnec-
tion in overvoltage category III conditions. The maximum per-
mitted current dispersion is 1mA/kW.
•
ble which is oil resistant, type H05RN-F or H07RN-F, for ca-
ble size consult the technical data table.
• Connect the power supply cable to the terminal board as
shown in the wiring diagram supplied with the appliance.
• Secure the power supply cable with the cable clamp.
• Protect the power supply cable on the outside of the applian-
ce with a rigid plastic or metal pipe.
• If the power supply cable is damaged, it must be replaced
by the manufacturer or the technical after-sales service or,
any risk whatsoever.
PROTECTIVE EARTH AND EARTH BONDING CONNEC-
TIONS
earth conductor to the terminal with the symbol
next to the main terminal board.
indicates:
-
-
located