Diagrama de flujo para solución de problemas
xx1800001836
Manual del producto - OmniCore C90XT
3HAC073706-005 Revisión: E
Problem releasing brakes
Check connec on
from X1 to
manipulator
Connec on ok
Check LED PS
Solid green
Check LEDs:
MS, PC, HMI
Solid green (all 3)
Measure power on
K2.X7
Power is ok
Check connec on
from K2.X7 to X1
Connec on is ok
Check connec on
K2.X6 to A1.X2
Connec on is ok
Test the brake
Brake is ok
Test the brake release
Brake release is ok
Problem solved
© Copyright 2020-2021 ABB. Reservados todos los derechos.
7 Solución de problemas
7.2.4 Problema al soltar los frenos del robot
Connec on not ok
Repair connec on
Not lit
Troubleshoot power
supply T2
Troubleshoot
- robot signal exchange
proxy K2
Abnormal
- power supply
- power unit
- main computer
- FlexPendant
No power
Repair connec on
Troubleshoot
Connec on
- brake release on
not ok
manipulator
-main computer A2
- robot signal exchange
proxy K2
- power unit A1
Connec on
not ok
Brake not ok
Not ok
Continúa en la página siguiente
Continuación
Contact ABB