Programme
1
Check the battery liquid
2
Check the wear and tear of suction motor carbon brushes
3
Check the wear and tear of brush motor carbon brushes
4
Clean the fi lter and the recovery tank
5
Remove deposits and impurities from the drainage tube
6
Check the wear and tear of squeegee blades. Contact edges must be intact, otherwise replace them
7
Check brush wear and tear
8
Replace brush
Defect
The machine does not start or it stops suddenly
The squeegee does not dry the fl oor properly
The scrubber-dryer sprays water towards the joints
between the tiles
The cleaning solution does not fl ow out or only a
small amount reaches the brushes
The machine is not cleaning well
The suction motor does not start
The brush does not rotate
MAINTENANCE AND CONTROL PROGRAMME
TROUBLESHOOTING
Cause
Batteries are exhausted
Batteries are not connected
3A main fuse, blown (see electric wiring diagram
for version BYTE 511, 511 T, 531, 612)
The ignition switch key has not been turned to po-
sition "1"
Fault, alarm is displayed
The squeegee suction hose is disconnected
The suction hose is clogged
Debris is caught in the squeegee
Suction loss
The hose and suction motor gaskets located under
the recovery tank are damaged
Squeegee blades are worn out
The squeegee has not been fi tted and adjusted pro-
perly
The brush water hose is clogged
(If provided) Solenoid valve damaged or dirty
Filter clogged or faulty
Brush totally worn out
Cleaning solution unsuitable
Brush not suitable for fl oor type
Excessive work speed
Batteries are not connected
Suction motor carbon brushes worn out
Suction motor disconnected or damaged
30A suction fuse, blown (see electric wiring diagram
for battery-operated machines with or without drive)
Batteries are not connected
Motor carbon brushes worn out
Motor disconnected or damaged
To be performed every....hours
8
Corrective action
Check charge status and recharge if necessary
Connect batteries (as per battery connection fi gure)
Check and replace if necessary.
Turn the key to said position
See "ALARM" table (version BYTE 531 T, 612 T)
Fit the hose back in place
Remove and clean the hose
Remove debris
Fix the leakage
Replace the gasket/s
Turn or replace the blades
Fit the squeegee properly and adjust it (see "Prepa-
ring the scrubber-dryer - fi tting and/or adjusting the
squeegee")
Clean the hose
Clean and/or replace the solenoid
Clean or replace the fi lter
Replace
Replace the cleaning solution
Use suitable brushes
Slow down
Connect the batteries
Check and/or replace
Check connection or replace motor
Check and replace if necessary.
Connect the batteries
Check and/or replace
Check connection or replace motor