DBI SALA 3400101 Manual De Istrucciones página 27

Ocultar thumbs Ver también para 3400101:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 86
◊ To Lower: First crank the crank arm counterclockwise to release
the fall arrest brake, then crank clockwise. The lowering function
is only intended to lower a person over a maximum distance of
2M.
IMPORTANT: A minimum load of 34 kg is required for lowering or
to pay out line. A maximum load for this device is 141KG. A force on
the retrieval handle of up to 13 kg is required to operate the winch
when loaded to capacity. In addition, there should always be direct
or indirect visual contact or some other means of communication
with the rescuee at all times during the rescue process.
CAUTION: Stop cranking when line is fully extended or retracted.
Continued cranking can damage components.
◊ Disengagement of retrieval mode: Remove any load from
the lifeline. Pull and hold the shift knob in the unlocked position.
Pull the crank arm out to the disengaged position and release
the shift knob. Secure the crank arm with the locking screw. Pull
out on the retrieval handle and rotate the handle to the stowed
position.
◊ Retrieval overload feature: Winches on the SRL models (as
shown in Figure 4) do not incorporate an overload clutch to limit
the force applied to the drive components and the person being
raised. Care must be taken to avoid line slack while in rescue
mode. Also, the individual must be monitored during retrieval
to ensure they do not become stuck and subjected to excessive
force from continued lifting.
IMPORTANT: Operating the retrieval system at loads greater than
the rated capacity reduces the overall safety factor. Any unit which
has been used above the rated capacity must be removed from
service and returned to Capital Safety for inspection.
◊ Mounting Retrieval Models: The SRL retrieval models (as
sjpwm on Figures 3 and 4) may be used with an optional bracket
(Model 3401025) for mounting to the Capital Safety tripod, davit
arm, or ladder mast. Follow the steps below for mounting and
use of this bracket.
IMPORTANT: If mating bracket for tripod leg is not attached,
position clamp plate assembly in desired location on leg and tighten
bolts to 20 Nm. Do not overtighten.
Step 1.
Remove the three set screws plugging the holes in the
side of the SRL housing. See Figure 24.
Step 2.
Attach the bracket to the SRL by inserting the three bolts
through the holes in the SRL housing. See Figure 25.