Step 3.
After the bracket is secured to the SRL, position the SRL
bracket assembly onto mating bracket of tripod, davit
arm, or ladder mast. The slot in the end of SRL bracket
slides onto pin extending out each side of mating ladder
mast, davit arm, or tripod leg bracket. Reposition tripod
leg bracket as required for proper operating height. See
Figure 26.
Step 4.
With assembly resting on pin, pivot top of SRL inward
to align holes. Press in button on end of detent pin and
slide pin in fully to secure SRL assembly to tripod, davit
arm, or ladder mast. See Figure 27.
Step 5.
Extend cable up support structure and over pulleys.
Reinstall detent pins near pulley to prevent cable from
sliding off pulleys. See Figure 28.
7.0
INSPECTION
The i-Safe™ RFID tag on SRLs (A) can be used in conjunction with the
i-Safe handheld reading device and the web based portal to simplify
inspection and inventory control and provide records for your fall
protection equipment. See Figure 29.
FREQUENCY: Before each use inspect SRL according to the
inspection steps below. SRLs must be inspected by a competent
person, other than the user, at least annually. If you are a fi rst-
time user, contact a Customer Service representative or if you
have already registered, go to: www.capitalsafety.com/isafe.html.
Follow instructions provided with your i-Safe handheld reader or
on the web portal to transfer your data to your web log. Record
the results of each formal inspection in the Periodic Examination
and Repair History in the GIUM (5902392) or use the i-Safe™
inspection web portal to maintain your inspection records. See
GIUM Section 4.
A record of annual service dates can be found on the SRL labels.
◊ After Fall Arrest: Inspect load impact indicator and entire SRL.
◊ After Use of Retrieval Mode: After raising or lowering, inspect
the load impact indicator and entire SRL. Applications which
require continuous raising and lowering may require increased
inspection and servicing frequency. Contact Capital Safety if you
have any questions regarding inspection frequency.
WARNING: See GIUM 1.2 if the SRL has been subjected to fall
arrest or impact forces.
IMPORTANT: Extreme working conditions (harsh environment,
prolonged use) may require increasing the frequency of inspections.