Assignment Of M 12 Plug - SICK C2000 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 107
Chapter 5
8008684/YJC8/2015-03-30
2 6 4
8 008 684/RI57/2007-11-28
Electrical Installation
5.2

Assignment of M 12 plug

S = Sender
Pin no.
Colour
1
White
2
Brown
3
Green
4
Yellow
5
Grey
6
Pink
7
Blue
8
R = Receiver
1
White
2
Brown
3
Green
4
Yellow
5
Grey
6
Pink
7
Blue
8
Fig. 5-4: Plug assignment for sender and receiver (standard, RES/EDM, cascadable)
of C 2000 and M 2000, nc = not connected
Multibeam Photoelectric Safety Switch M 2000
Designation
Meaning (I = Input, O = Output)
SEL 1
I: Beam coding (see Tab. 5-1)
+ 24 V DC
Voltage supply, U
SEL 2
I: Beam coding (seeTab. 5-1)
nc
Vacant
TEST
I: 24 V = Self-test, 0 V = External test
HRANGE
I: Sender range (standard, RES/EDM),
(M 2000)/
0 V = 0 ... 6 m, 24 V = 2 ... 25 m
nc (C 2000)
Cascadable: if M 2000 is in cascade,
0 V = 0 ... 6 m, 24 V = 2 ... 25 m,
Only C 2000 in cascade: nc
GND
0 V, voltage supply
Shield
Functional earth
SEL 1
I: Beam coding (see Tab. 5-1)
+ 24 V DC
Voltage supply, U
SEL 2
I: Beam coding (see Tab. 5-1)
EDM
I: External device monitoring, 24 V supplied
via series connection of two NC contacts of
machine contactors
OSSD 1
O: Switching output 1
OSSD 2
O: Switching output 2
GND
0 V, voltage supply
Shield
Functional earth
© SICK AG • Safety Systems • Germany • All rights reserved
Operating Instructions
Safety Light Curtain C 2000
B
B

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M2000

Tabla de contenido