The LED (8) will flash when the compressor is on while if
the set value has been reached, they will only remain lit
until transition to storage. Similarly with storage, the LED
(9) will flash when the compressor is active and will remain
lit for the rest of the storage.
7.2 Chilling phases
Pressing the positive chilling button (2) or negative chilling
button (3) allows selection of a different chilling mode. The
number of LEDs lit (23) or (24) define the "intensity" of chill-
ing. The "Time" or "Temperature" chilling mode will be set
by pressing the button (5). Lighting up of the corresponding
LEDs on the sides will define the type of chilling
Each time the positive chilling button (2) is pressed the display
will show successively for 3 seconds one of the following cycles:
LIGHT, SOFT, MEDIUM, FAST
Each time the negative chilling button (3) is pressed the display
will show successively for 3 seconds one of the following cycles:
LIGHT, SOFT, HARD, RUN
7.3 Selecting and starting the Positive chilling
cycle
When the button (2) is pressed for the first time,"SOFT"
mode will be selected, represented with lighting up of two
of the four LEDs (24); subsequent pressing takes to 3 and
4 the LEDs lit and results in the "HARD" mode. Successive
pressing reduces from 4 to 1 the LEDs lit and so on.
"LIGHT" - 1 LED only on
In this condition, there will be a cell temperature set of -3°C.
This avoids the risk of ice formation during the positive
chilling phase and it will be used for loads which can be
damaged by excessively heavy treatment (vegetables etc.)
"SOFT" - 2 LEDs on (Default)
In this condition, there will be a cell temperature set of -5°C.
This set will allow quicker chilling for products that in any
case are fairly resistant to the freezing process.
"MEDIUM" - 3 LEDS on
In this condition, there will be an initial cell temperature set
of -20°C; after the HARD time, this will be taken to a cell
temperature of -3°C. This method accelerates cooling in the
presence of products that are resistant and very hot initially.
"FAST" - 4 LEDs on
In this condition, there will be an initial cell temperature set
13
of -20°C; after the HARD time, this will be taken to a cell
temperature of -5°C. This method accelerates cooling in the
presence of products that are resistant and very hot initially.
With the MEDIUM or FAST temperature chilling, the set
change will be decided by the product temperature detected
according to the parameter (Cd).
Once the MEDIUM or FAST cycles are started, to modify
the HARD phase duration simply press the button (2) that
will show on the display (19) the words "Hard" and will result
in flashing on the display (18) the value in minutes of the
HARD phase. With the +/- buttons it is possible to increase
or decrease this value and confirm with the button (2) or wait
5 seconds (N.B. THE CHANGED VALUE ONLY APPLIES
TO THE CYCLE IN PROGRESS).
Once the cycle is selected, it is necessary to select the Time or
Temperature mode by pressing the button (5) until coming on of
the relevant LED�
At this point to start the cycle press the START/STOP button (22)
In the event of Temperature chilling, it is possible to change
this chilling end value by pressing the button (2) or (3) de-
pending on the type of chilling in progress. Having pressed
the button, the display (19) will show the lettering "Set" and
on the display (18) will appear the value of the end chilling
temperature set, which can be modified within the envis-
aged range. Having pressed the button (2) or (3) or after 5
seconds the changed value is saved.
7.4 Selection and starting the Negative chill-
ing cycle
Pressing the button (3) for the first time will select the
"HARD" mode, represented by coming on of three of the
four LEDs (23) present. Subsequent pressing will take to 4
the LEDs lit and will return into "RUN+HARD" mode. Suc-
cessive presses reduce from 4 to 1 the LEDs and so on.
"LIGHT" - 1 LED only on
In this condition, there will be an initial cell temperature set
of -5°C; after the SOFT time defined by the parameter (ts)
this will move to a temperature of -30°C. This mode is for
use on large pieces where it is important to homogenise
the chilling cycle.
71503136-0-R000