"End Cycle - Fine ciclo" will appear. At that time the cycle
will go into storage.
To see the value of the insert probe during thawing, simply
press the button (12) which will display the product probe
value for 5 seconds flashing on the display (18) and the
wording "SP1" and "SP2" is shown on the display (19) to
distinguish the probe reading.

14 CHILLING PROGRAM STORAGE

The user has the button (16), which allows the saving or
recalling of 99 chilling cycles.
To store a chilling cycle the user must:
1) set a chilling type (buttons (1)-(2) ).
2) set the mode of chilling (by temperature or by time, but-
ton (5) ).
3) set the total time or the final temperature +/- buttons.
4) press and hold (long press) the "PROGRAM" button (16)
until the beeper emits a beep; the LED of the button starts to
flash. On the basis of the first display it will flash signifying
waiting for setting of the first letter/number.
4) then using the keys +/- set the first letter/number and
confirm with the button (5). This will confirm the value,
passing on to the next one. Arriving at the ninth character
or even before, it is possible to press the START button for
start and storage (ATTENTION, if a program with the same
name already exists, it will be overwritten).
5) press START/STP (22).
With Start the software stores the "type" and "mode" of
chilling selected.
To discontinue saving of the program, press the storage
button again or wait for the Time out (approximately 10 sec.).
If time chilling has been set, the duration set is stored.
In the case of Temperature chilling, it will store the time in
which the insert probe reaches the PRODUCT TEMPERA-
TURE SET set, and will store this time as duration of the
chilling.
In addition, if the chilling is Positive Hard, it also saves the
time necessary to reach the core at +20°C (Hard))
When saving a temperature (insert probe) chilling cycle, the
LED of the programming button flashes to indicate that stor-
age of the times is in progress. As soon as the temperature
chilling cycle ends, the LED stops flashing to indicate that
storage has been successful.
If storing a temperature cycle, this stops (due to alarms,
16
button stop, etc.), the cycle times are not saved. The initial
settings however remain saved.

15 CHILLING PROGRAM EXECUTION

To call up and run a memory-resident program, the user
must:
1) press the "PROG" button (short press), the LED lights up
and with the +/- buttons, select one of the saved programs.
2) press START
If the save button is pressed by accident, pressing it again
will exit that function.
While a program is running, by pressing the "PROG" button,
the display shows the name of the program in progress.

16 ALARMS

Summarised here are the main alarms that can appear and
that will be represented by the scrolling text on the display:

16.1 Evaporator probe alarm

Cause: Being outside the operating range (-50°C / +100°C)
for more than 30 seconds.
Effect: Interruption of any defrosting in progress. Inhibition
of all periodic defrosting. Inhibition of manual defrosting
(except forcing of fans with machine at standstill).
Beeper: The beeper sounds (3 seconds and then pauses
for 30 seconds) until the silencer button is pressed.
Display: The display shows the scrolling text "AL01 - SON-
DA EVAPORATORE DIFETTOSA - FAULT EVAPORATOR
PROBE
Flashing RED symbol (14)
Reset: It resets by itself if the value of the probe falls (ap-
proximately 20 seconds), or if the probe is excluded with
parameter "/5"

16.2 Product probe alarm

Cause: Being outside the operating range (-50°C / +100°C)
for more than 30 seconds with a temperature chilling cycle
in progress.
Effect: Interruption of the temperature chilling cycle in pro-
gress resulting in automatic start of Time chilling. Inhibition
of temperature chilling button.
Beeper: The beeper sounds (3 seconds and then pauses for
71503136-0-R000