Risk of accident due to pneumatic tubing slipping off!
Use shortest possible tubing connections.
If pneumatic tubing slips off:
Switch off the compressed air supply immediately.
Do not exceed the maximum permissible pressure of 6 bar (600 kPa).
Do not switch on the compressed air until all the tubing connections have been
established and secured.
Do not disconnect pneumatic tubing while under pressure.
Do not attempt to connect pneumatic tubing or push-in connectors with your
hands or fingers.
Pneumatic circuit setup:
Connect the devices with plastic tubing with an outside diameter of 4 or 6 mm.
Push the pneumatic tubing into the push-in connector as far as it will go.
Switch off the compressed air supply before dismantling the circuit.
Dismantling the pneumatic circuit
Press the blue release ring down so that the pneumatic tubing can be pulled out.
Noise due to escaping compressed air
Noise caused by escaping compressed air may damage your hearing.
Reduce noise by using pneumatic mufflers, or wear hearing protection if noise
cannot be avoided.
All of the exhaust ports of the components included in the equipment sets are
equipped with mufflers. Do not remove these mufflers.