Descargar Imprimir esta página

Eurofred 4T Manual De Instalación, Uso Y Mantenimiento página 231

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 129
In implementation of the European Regulation 1095/2015
Type of product :
Blast Chiller and Blast Freezer
Refrigerant fluid(s)
R452A [GWP 2141]
Blast chilling Program +3°C Hard
Blast freezing Program -18°C Hard
Energy
Model
Consumption Consumption
chilling
function
kWh/kg
Neos 4T
0,095
Neos 5T
0,067
In implementation of the European Regulation 1095/2015
Type of product :
Blast Chiller and Blast Freezer
Refrigerant fluid(s)
R290[GWP 3]
Blast chilling Program +3°C Hard
Blast freezing Program -18°C Hard
Energy
Model
Consumption Consumption
chilling
function
kWh/kg
Neos 4T
0,098
Neos 5T
0,069
Energy
Chilled
Frozen Refrigerant
full
freezing
load
function
capacity
capacity
kWh/kg
kg
0,305
12
0,312
18
Energy
Chilled
Frozen Refrigerant
full
freezing
load
function
capacity
capacity
kWh/kg
kg
0,302
12
0,311
18
Blast
full
charge
Chilling
load
cycle from cycle from chilling
+65°C to
+10°C
kg
kg
min
8
1
90
10
1
92
Blast
full
charge
Chilling
load
cycle from cycle from chilling
+65°C to
+10°C
kg
kg
min
8
0,15
93
10
0,15
95
XI
Blast
Program Program
Freezing
Blast
Blast
freezing
+65°C to
-18°C
min
234
Hard +3°C Hard -18°C
215
Hard +3°C Hard -18°C
Blast
Program Program
Freezing
Blast
Blast
freezing
+65°C to
-18°C
min
241
Hard +3°C Hard -18°C
222
Hard +3°C Hard -18°C

Publicidad

loading

Productos relacionados para Eurofred 4T

Este manual también es adecuado para: